Question:

My airconditioner keeps shutting off and puts E-4 on my thermastatcan you tell what to do

by Guest9159  |  12 years, 7 month(s) ago

0 LIKES UnLike

My airconditioner keeps shutting off and puts E-4 on my thermastatcan you tell what to do

 Tags: Airconditioner, E4, Shutting, Tell, thermastatcan

   Report

1 ANSWERS

  1. Guest843
    If unit displays "e4"

    1、 Check whether the winding resistance and
    operation current of the compressor are normal.
    2、Check whether the high and low pressure is normal
    when the unit is running.
    3、Check (whether the coil pipe sensor is normal)
    whether the contact of the inserter on the circuit
    board is well, the coil pipe temperature sensor is
    fixed, the evaporation of the indoor unit is well,
    the key is to check the evaporator temperature
    detected by the coil pipe temperature sensor has
    reached the cooling or heating temperature.
    4、Check whether the surface of the condenser is too
    dirty, it should be cleaned when it is too dirty.
    5、Check whether the capacitance of the outdoor motor
    and the fan is damaged, it should be replaced when
    it is damaged.
    6、If the above items are normal, the electric control
    board should be replaced.

Sign In or Sign Up now to answser this question!

Question Stats

Latest activity: 13 years, 8 month(s) ago.
This question has 1 answers.

BECOME A GUIDE

Share your knowledge and help people by answering questions.